2160-200

2160-200

 

Used as a direct-reading DC voltmeter, this Digital Panel Meter (DPM) model provides a full-scale readout of ±20,000 counts (selectable fixed zero or active least significant digit) and five full-scale voltage ranges/resolutions (see Specifications).  Accuracy is 99.99% of full scale ± 1 count. To minimize the load on the voltage signal, a high input impedance is provided (up to 1 GΩ for the 200.00-mV and 2.000-V ranges).  The maximum voltage which can be applied on the 20, 200, and 660 V-DC range is 660 V-AC.

2160-20

2160-20

 

Used as a direct-reading DC voltmeter, this Digital Panel Meter (DPM) model provides a full-scale readout of ±20,000 counts (selectable fixed zero or active least significant digit) and five full-scale voltage ranges/resolutions (see Specifications).  Accuracy is 99.99% of full scale ± 1 count. To minimize the load on the voltage signal, a high input impedance is provided (up to 1 GΩ for the 200.00-mV and 2.000-V ranges).  The maximum voltage which can be applied on the 20, 200, and 660 V-DC range is 660 V-AC.

2160-2

2160-2

 

Used as a direct-reading DC voltmeter, this Digital Panel Meter (DPM) model provides a full-scale readout of ±20,000 counts (selectable fixed zero or active least significant digit) and five full-scale voltage ranges/resolutions (see Specifications).  Accuracy is 99.99% of full scale ± 1 count. To minimize the load on the voltage signal, a high input impedance is provided (up to 1 GΩ for the 200.00-mV and 2.000-V ranges).  The maximum voltage which can be applied on the 20, 200, and 660 V-DC range is 660 V-AC.

2160-002

2160-002

 

Used as a direct-reading DC voltmeter, this Digital Panel Meter (DPM) model provides a full-scale readout of ±20,000 counts (selectable fixed zero or active least significant digit) and five full-scale voltage ranges/resolutions (see Specifications).  Accuracy is 99.99% of full scale ± 1 count. To minimize the load on the voltage signal, a high input impedance is provided (up to 1 GΩ for the 200.00-mV and 2.000-V ranges).  The maximum voltage which can be applied on the 20, 200, and 660 V-DC range is 660 V-AC.

3KPLUS-64

3KPLUS-64

 

Incorporating the 5D Series Signal Conditioner Modules, the 3000PLUS is a field-scalable indicator with operator-programmable signal processing and PC/PLC communications.  With a durable front panel and secure screw terminals for all power and I/O connections, this mechanically and electrically rugged instrument is ideal for pump, motor, hydraulic, and other high-noise monitoring applications.